Products Contact Us Jobs About Arcom Tech Support Applications Events Home
AIM104-OUT16

16 Opto-isolated Darlington driver outputs

Technical Documentation: Arcom provides on-line access to detailed technical documentation to help you select the best product for your application. Click here to download the manual for the AIM104-OUT16 PC/104 I/O module.

Features
16 opto-isolated Darlington driver outputs
30V max load operating voltage
40KHz max output frequency
Catch diode on all outputs for protection when driving inductive loads
Module access LED
 
Specification
Comms. channels: 16 opto-isolated Darlington driver outputs
Max output frequency: 40KHz 
Electrical isolation: 1500V
Inter-channel isolation: 100V
Max. sink current (outputs 0 to 4): 600mA
Max. sink current (outputs 5 to 15): 300mA
Base address range: 0 to 3FC hex
I/O space required: 4 bytes
I/O Connector: 26-way Ribbon
Mechanical: Standard PC/104: 96mm (3.8-in) by 90mm (3.5-in)
Power requirements: 125mA @ 5V
Operating temperature: -20°C to 70°C
MTBF: 700,000hrs
Storage temperature: -40 to 125°C
Software Support: 